The main concern from florida building code is that any structures or vents that may reside on the flat roof must be properly fastened and sealed.
Roof venting in florida.
In northern areas the warm moist side of the attic that needs to be vented is on the underside of the roof structure.
Roof ventilation in a cold climate vents moisture and ensures a cold roof temperature to avoid ice dams.
In florida the cool side of the attic is the conditioned space and the warm side that needs to be vented is on the ceiling structure.
Attic spaces designed by a florida licensed engineer or registered architect to eliminate the attic venting.
Single family residential structures permitted subject to the florida building code are not required to comply with this section.
The economical version of such shingles aka 3 tab are poor choice for any area with high speed winds.
Fbc section 1203 2 continued ventilation attic spaces.
Drip edge vents are a two in one installation that promote water shedding at the eaves and rakes of a roof while also allowing for ventilation into the attic.
It comes on an easy to install flexible mesh roll and is hand nailable with no complicated fitting wrapping nail gun adapters connectors or end plugs needed.
Asphalt shingles are the number one selling roofing material in the u s.
2010 florida building code mechanical 4 1 b 402 2 ventilation area required.
Proper attic ventilation in florida the typical method for ventilating the attic on an average home is soffit and ridge vent.
Shingle over or nonshingle over vent types along the length of the roof.
Fbc section 1203 2 newer studies newer ashrae studies have found that the practice of attic ventilation to be detrimental to structures in warm humid climates.
When installed as part of a properly balanced when installed as part of a properly balanced attic ventilation system gaf cobra exhaust vent is a shingle over exhaust vent installed at the roof ridge that helps exhaust excess heat and moisture from your attic.
Roof to wall connections shall be improved as required by section r908 8 1.
Rely on wind to rotate the vent s turbine.
If you don t have soffits or your roof style doesn t allow for soffit vents some homeowners will consider a drip edge vent.
I come across many homes that originally had soffit venting and wind turbines at the peak but continuous ridge venting was added later during a re roof.
I suspect the thinking was the more the better.
In a hot climate roof vents expel hot air from the roof or attic while relieving the load on the air conditioning system.
Installed in the walls of a building at the gable end s peak.
As the name suggests installed near the ridge of the roof.